When you order a McDaniel fillable gauge you may
            choose to fill it yourself or you may order it factory-filled with the liquid of your
            choice. Thus you can maximize inventory utility and
            minimize inventory cost.
            
               Glycerin filling  has a lower operating temperature limit of
            32ºF (0ºC) 
            undiluted.  The mixture of distilled water in proportions up to 35% will lower the
            limit commensurately, to -40ºF (-40ºC).
               Silicon can extend the lower temperature limit to
            -60ºF(-50ºC).
               The maximum temperature limit is not determined by
            the fluid but by the gauge's synthetic case seal.  At elevated temperatures the seal
            may bake and lose elasticity.
            
              
                | Warning:
                Glycerin filled gauges should not be used in applications involving strong
                oxidizing agents such as chlorine, nitric acid or hydrogen peroxide. (Refer to ASME B40.1) |